The phrase hipot test means high potential or high voltage test. Another name used to refer to this test is dielectric withstand test. This is an analysis of electrical components that is done with the intention of checking for suitability of electrical insulation. The analysis is meant to ensure that there is no current leakage from one point to another in electrical devices. It is the opposite of continuity test. This is worth knowing about Hipot tester.

The test is nondestructive and capable of determining the sufficiency of electrical insulation. The test uses high voltage. The high voltage is applied to all electrical appliances for a certain time duration to ensure the insulation is more than marginal. High quantities of voltage are applied to the insulation in the process.

Determining the availability of nicked or crushed insulation in a component is part of the goal of the process. Also, the process assists in identification of corrosive or conductive contaminants, stray wire strands, and braided shielding around conductors. By using hipot testing, one can easily identify terminal spacing problems and tolerance errors in cables. Compared to operating voltage, the voltage that is normally applied in this process is two times greater.

Hipot analyzers are the devices applied in Hipot testing. One side of the supply is normally connected to safety ground in a typical tester. The other side of the supply connects the conductor that has to be tested. Only two forms of contact to which the conductors can be linked exist in this arrangement. That is the voltage and ground.

In cases where there are 2 contacts that have to be connected, then one needs to be linked to the voltage whereas the other one is connected to ground. This type of connection is crucial as it guarantees that contacts get isolated from other kinds of contacts. If insulation between the two conductors is insufficient, then a small charge will flow between the two conductors when a massive voltage is passed through.

Even though the flow of such a small current is usually acceptable, a breakdown of solid or air insulation is not supposed to occur in any case. High voltage is usually used in these tests because it is believed that any product is usually subjected to normal day-to-day transient over voltages. As such, in case such variations in voltages occur during the day, the product is supposed to remain operational and safe.

There are different standards that are usually observed when conducting this analysis. The various standards require the voltage to be applied for different amounts of time. Under the IEC 06950, the analysis is supposed to be continued continuously for a duration of one minute. However, a typical rule of thumb is to apply 110 to 120 percent of operating voltage of the product plus 1000 volts for 1 to 2 seconds.

Specifications for the quantity of current which an individual should apply also exist. Many types of different testers which a person can purchase easily exist in the current market. Varying testers are designed for varying categories of products. Therefore, knowing the tester to apply for specific applications is vital.